"FİLKRET 500" dry concrete repairing mortar

"FİLKRET 500" dry concrete repairing mortar

Product consumption calculator


Preorder


Terms of use

Print


Product Description

Filkret 300 is a cement based dry concrete repairing mixture, monocomponent, polymerizable, having high stability. The product conforms to the requirements of the 039-2000 (TS 11140-1993) standard: “Adhesives – cement based (hydraulic conjunction), suitable for glazed, ceramic, and floor tiles”.

Fields of Application

This repair mixture can be applied in the following areas:

  • repair and plastering of dry concrete surfaces;
  • alignment of corner edges  during plastering and repair of walls and ceilings;
  • correction of irregularities on surfaces before laying ceramic and glazed tile facings.

Advantages

  • the product is mixed with water only, easy applicable;
  • provides high adhesive ability to concrete and plastered surfaces;
  • easily applicable on large surfaces;
  • does not form cracks;
  • possesses high thixotropic properties;
  • resistant to water and to humid, frosty and warm weather conditions.

Method of application

Preparation of the surfaces. Cement based surfaces to be repaired should be rigid, clean and dust-free, they should be totally free of any fat, rust, and paraffin residues deteriorating adhesive force. The surface should be cleaned from metal and wooden particles, and all cavities up to 4cm deep should be filled with MATON 200 repair mixture. Provide water saturation of the surface to be treated with the mixture, however there should not be free water remained on the surface.

Preparation of the mixture. Pour appropriate amount of water measured with the help of a measuring device into clean container, and gradually add the Filkret 500 repair mixture. Prepare this mixture for 4 minutes using 400-600 RPM mixer till the mixture becomes entirely homogeneous. Mix again in approximately 4 minutes during 30-minute period, bringing the product to conditions ready for application.

Application. Spread the prepared mixture over the surface with to form 1 – 5mm thick layer using trowel. Let the mixture dry, and splash water on the surface of the mixture surface using plaster brush. Then correct the surface in required manner using steel or wooden trowel. In case of applying of the Filkret 500 product in the open area on large open surfaces, especially in the warm, dry and windy weather conditions, prevent evaporation of the solution during 24-48 hours using soaked cloth, duck fabric, or any other active solution.

Recommendations. Once prepared for repair works the Filkret 500 product should be used within 30 minutes at +200C temperature. For +320C temperature this period is reduced to 20 minutes. In case of the product application on external surfaces they should be protected from direct sun rays, wind, rain and/or frost during 24 hours. Application and reaction rate of cement based systems can be affected by the ambient temperature and other conditions, including the air humidity. Low temperatures elongate the hydration period, and result in increase of the product effective life. High temperatures reduce the hydration period, and result in decrease of the above mentioned period. To provide full hardening of the mixture the ambient temperature should not drop below the specified minimum values. After use all hand tools and devices should be cleaned with water.

Consumption

The required amount of the mixture consumed to obtain 1mm thick layer shall be 1.48 kg/m2.

Shelf Life and Storage Method

The product can be stored during 12 months packed in original sacks in dry and cold conditions. For the short storage period the sacks can be placed one upon the other in three layers. In case of long-term storage the product packages should not be laid one upon another. The product in unpacked sacks should be used within one week provided the required storage conditions are maintained.

Warnings

  • when using the repair mixture observe regulations of operational and personnel safety, wear appropriate protective clothing, safety gloves, glasses, and respirators;
  • to provide protection from harmful effect of non-hardened substance, in case of contact with skin or eyes immediately rinse them with large amount of water and wash with soap;
  • in case you swallow the product, immediately consult a physician;
  • do not keep food products in the areas of the solution application;
  • keep the product away from children;
  • parameters indicated above have been received on the basis of laboratory tests conducted in the ambient conditions of +230C±20C temperature and 50% + 5% humidity. Depending on the actual ambient conditions these parameters are subject to change.

Warranty and technical support

  • information indicated in technical specifications is based on scientific and experimental data;
  • Matanat А company is responsible for the product quality only;
  • with the exception of cases of works executed under the supervision of the company specialists, Мatanat  А company shall not be liable for any problems occuring due to improper use of the product by other persons;
  • the company reserves the right to make changes in its product in consequence of scientific-and-technical development;
  • for technical support and/or more information please do not hesitate to contact the Matanat А company!